Orbital blowout fracture due to trauma - postoperative photo
The postoperative photo of the previous case, after fixation with a mini plate in the orbital rim and zygomatico frontal suture. Titanium mesh was used for prevention and separation of the orbital content from entering the maxillary sinus.